Evaluation of different Life Cycle Impact Assessment (LCIA) indicators for tree different water supply technologies. The calculation includes the production of Reverse osmosis seawater treatment plant, membrane water treatment plant, ion exchanger water treatment plant with a capacity of 3.000.000 m3/a each.
Metadata
Unit:
see Internal ID
Spatial resolution:
Germany
Period:
2020,2030,2050
Internal ID:
internal_id_type[1] = 127: type of water treatment plant internal_id[1] = 7: Reverse Osmosis Seawater Treatment Plant internal_id[1] = 8: Membrane water treatment plant internal_id[1] = 9: Ion exchanger water treatment plant
internal_id_type[2] = 70: Environmental indicators internal_id[2] = 1: cumulative energy demand | fossil | non-renewable energy resources, fossil | in MJ-Eq internal_id[2] = 2: IPCC 2013 no LT | climate change | GWP 20a | in kg CO2-Eq internal_id[2] = 3: IPCC 2013 no LT | climate change | GWP 100a | in kg CO2-Eq internal_id[2] = 4: ReCiPe Midpoint (H) V1.13 no LT | agricultural land occupation | ALOP | in m2a internal_id[2] = 5: ReCiPe Midpoint (H) V1.13 no LT | climate change | GWP100 | in kg CO2-Eq internal_id[2] = 6: ReCiPe Midpoint (H) V1.13 no LT | fossil depletion | FDP | in kg oil-Eq internal_id[2] = 7: ReCiPe Midpoint (H) V1.13 no LT | freshwater ecotoxicity | FETPinf | in kg 1,4-DC. internal_id[2] = 8: ReCiPe Midpoint (H) V1.13 no LT | freshwater eutrophication | FEP | in kg P-Eq internal_id[2] = 9: ReCiPe Midpoint (H) V1.13 no LT | human toxicity | HTPinf | in kg 1,4-DC. internal_id[2] = 10: ReCiPe Midpoint (H) V1.13 no LT | ionising radiation | IRP_HE | in kg U235-Eq internal_id[2] = 11: ReCiPe Midpoint (H) V1.13 no LT | marine ecotoxicity | METPinf | in kg 1,4-DB. internal_id[2] = 12: ReCiPe Midpoint (H) V1.13 no LT | marine eutrophication | MEP | in kg N-Eq internal_id[2] = 13: ReCiPe Midpoint (H) V1.13 no LT | metal depletion | MDP | in kg Fe-Eq internal_id[2] = 14: ReCiPe Midpoint (H) V1.13 no LT | natural land transformation | NLTP | in m2 internal_id[2] = 15: ReCiPe Midpoint (H) V1.13 no LT | ozone depletion | ODPinf | in kg CFC-11. internal_id[2] = 16: ReCiPe Midpoint (H) V1.13 no LT | particulate matter formation | PMFP | in kg PM10-Eq internal_id[2] = 17: ReCiPe Midpoint (H) V1.13 no LT | photochemical oxidant formation | POFP | in kg NMVOC-. internal_id[2] = 18: ReCiPe Midpoint (H) V1.13 no LT | terrestrial acidification | TAP100 | in kg SO2-Eq internal_id[2] = 19: ReCiPe Midpoint (H) V1.13 no LT | terrestrial ecotoxicity | TETPinf | in kg 1,4-DC. internal_id[2] = 20: ReCiPe Midpoint (H) V1.13 no LT | urban land occupation | ULOP | in m2a internal_id[2] = 21: ReCiPe Midpoint (H) V1.13 no LT | water depletion | WDP | in m3 water